! Only for educational purposes, the source might not be synchronized with the
|
|
! latest release!
|
|
! For normal operation, use the RFLink Loader that includes the latest release
|
|
! ============================================================================
|
|
|
|
Please note that the RFLink Gateway is a freeware project.
|
|
Stuntteam is not making money in any way.
|
|
This means that there are no unlimited funds to purchase test devices,
|
|
it also means the project has to rely on you, the user, to send debug data.
|
|
|
|
If you want to contribute to this project, you can send a donation which is more than welcome (see www.nemcon.nl/blog2 donation button),
|
|
or help with sending debug data of unsupported devices (you can even write and contribute plugins and/or code fixes),
|
|
or donate the device that you would like to see supported.
|
|
|
|
Right now we are looking for some older remotes and/or switches.
|
|
Like for example: Impuls, Ikea Koppla, Powerfix, Blyss, Home Confort, Conrad, Kambrook, Everflourish
|
|
For the implementation of the planned 2.4Ghz support we could use some simple MySensor devices.
|
|
For the implementation of the planned 868Mhz support we could use some devices as well.
|
|
If you have anything that you do not use, send a mail to frankzirrone@gmail.com
|
|
Thanks in advance!
|
|
|
|
------------------------
|
|
Synology NAS:
|
|
If you want to use RFLink with a Synology NAS you can use:
|
|
- an Arduino Mega clone based on CH340 USB/serial chip
|
|
In all other cases:
|
|
- connect a 10 uF capacitor between reset and ground on the Arduino.
|
|
Simply stick the pins of the capacitor in the power connector socket.
|
|
When you want to update the firmware of the Arduino, remove the capacitor and reconnect it when done.
|
|
For details about the Domoticz Synology package check out: http://www.jadahl.com
|
|
------------------------
|
|
RFlink via Network Connection:
|
|
It is possible to use RFlink via a network connection using ser2net.
|
|
------------------------
|
|
You can now use the RFLink Gateway with the following home automation software:
|
|
Domoticz
|
|
Jeedom
|
|
------------------------
|
|
R35: (Work-In-Progress) Build 05
|
|
- Added: Brel motor support
|
|
- Fixed: Oregon OWL CM119, CM160, CM180
|
|
- Fixed: Corrected WH440 temperature values
|
|
- Fixed: Improved Philips SBC
|
|
- Fixed: Improved Chacon EMW200
|
|
- Fixed: Removed a slash in the UPM/Esic name
|
|
- Tested: tested and working: Lidl / Libra TR502MSV switches
|
|
|
|
R34:
|
|
- Added: Heidemann HX Silverline 70290
|
|
- Added: Eurochron EAS 301Z / EAS 302
|
|
- Added: Znane-01 switch set sold at Biedronka (Impuls clone)
|
|
- Added: HomeEasy HE800 protocol support
|
|
- Added: Fine Offset Electronics WH2, Agimex Rosenborg 66796, ClimeMET CM9088
|
|
- Added: Somfy Smoove Origin RTS (433mhz) (receive)
|
|
- Tested: Eurodomest 972086 (Sold at Action in Belgium)
|
|
- Added: Eurodomest revised protocol (full autodetection)
|
|
- Added: Prologue temperature sensor support
|
|
- Tested: tested and working: Home Confort, Smart Home PRF-100 switch set
|
|
- Fixed: Auto detection of "Emil Lux"/LUX-Tools remote control/switch set (Sold at Obi.de Art.Nr. 2087971) (Impuls clone)
|
|
- Fixed: Alecto WS1100 working properly again (Adjusted pulse range and displayed humidity value)
|
|
- Fixed: Byron SX receive and send commands
|
|
- Fixed: Ikea Koppla Send routines
|
|
- Fixed: Improved the Impuls remote detection
|
|
- Fixed: Impuls transmit
|
|
- Changed: added checks for valid temperatures in various plugins
|
|
|
|
R33:
|
|
- Updated RFlink loader to version 1.03 to include a serial log option with command sending ability!
|
|
|
|
- Added: Full automatic 'Flamingo FA500/SilverCrest 91210/60494 RCS AAA3680/Mumbi M-FS300/Toom 1919384' protocol support! (send & receive!)
|
|
Note: re-learn your FA500 Remote in Domoticz
|
|
- Added: Unitec 48111/48112 (receive)
|
|
- Added: Avidsen
|
|
- Added: Somfy Telis (433mhz) (receive)
|
|
- Fixed: Extreme temperature value rejection for various sensor types (TFA/LaCrosse)
|
|
- Fixed: Improved Blyss send routines
|
|
- Added: Support for old Xiron temperature sensor in Cresta plugin (Temperature only sensor was not handled)
|
|
- Added: Biowin meteo sensor
|
|
- Fixed: Imagintronix humidity and temperature values were sometimes incorrect
|
|
- Fixed: AB4400/Sartano/Phenix detection corrected
|
|
- Fixed: Modification to allow EMW200/203 to work better
|
|
- Changed: ARC (and compatible) remote and switch handling improved
|
|
- Fixed: Improved Impuls handling
|
|
- Fixed: Auriol V3 minus temperature handling
|
|
- Fixed: TRC02RGB send
|
|
- Fixed: Oregon OWL180 data
|
|
- Changed: Aster signal detection so that L^Home model 32311T is recognized as well
|
|
- Changed: ID for Nodo Slave 'Wind direction/Wind gust' combined so that Domoticz can handle the data
|
|
- Changed: Protocol handling order for 'multi-protocol' transmitting devices
|
|
|
|
R32:
|
|
- Added: Europe RS-200, Conrad TR-200
|
|
- Added: Bofu motor transmit
|
|
- Added: ARC group command support
|
|
- Added: support for ARC based tri-state protocol
|
|
- Tested and working: Hormann 868mhz receive
|
|
- Changed: Bofu motor signal repetition detection improved
|
|
- Fixed: Aster transmit routines
|
|
- Fixed: plugin 003 output was not processed correctly by Domoticz
|
|
- Fixed: ARC higher address numbers did not work correctly in combination with Domoticz
|
|
- Changed: Chacon/Powerfix/Mandolyn/Quigg transmit routine and optimized timing
|
|
- Changed: Increased the number of re-transmits in the Home Easy protocol to improve signal reception and distance
|
|
- Changed: Sensor plugins now suppressing ARC derived protocols a bit better
|
|
|
|
R31:
|
|
- New Device: Forrinx Wireless Doorbell
|
|
- New Device: TRC02 RGB controller
|
|
- New Device: OWL CM180
|
|
- New Device: ELMES CTX3H and CTX4H contact sensor
|
|
- New Device: Bofu Motor (receive)
|
|
- New Device: Aster / GEMINI EMC/99/STI/037
|
|
- Changed: EV1527 based sensors were reported as X10, now they are reported as EV1527. Note that it might be needed to re-add the devices to Domoticz
|
|
- Changed: increased number of retransmits for ARC and AC protocols
|
|
- Fixed: Koppla switch number was incorrect
|
|
- Fixed: Powerfix/Mandolyn/Chacon Parity calculation in send routines
|
|
- Fixed: Powerfix/Mandolyn/Chacon timing
|
|
- Fixed Windspeed value for WS2300
|
|
- Fixed: Home Easy HE300 ON/OFF signal was reversed
|
|
- Changed: HomeEasy suppressing additional protocol data to avoid reporting the same event multiple times under different protocols
|
|
- Fixed: More fixes to avoid duplicate reporting of the same event (various protocols)
|
|
|
|
R30:
|
|
- New Device: Conrad 9771 Pool Thermometer
|
|
- New Device: SilverCrest Z31370-TX Doorbell
|
|
- New Device: Smartwares remote controls (among others: SH5-TDR-K 10.037.17)
|
|
- New Device: Chuango Alarm devices Motion/Door/Window etc. (among others: CG-105S)
|
|
- New Device: Oregon Scientific NR868 PIR/night light
|
|
- New Device: Oregon Scientific MSR939 PIR
|
|
- New Device: Imagintronix Temperature/Soil humidity sensor
|
|
- New Device: Ikea Koppla (receive)
|
|
- New Device: Chacon (TR-502MSV, NR.RC402)
|
|
- Fixed: Arc protocol send
|
|
- Fixed: Impuls. Note: pair devices with the KAKU protocol, the remote is recognized separately. (Needs more tests!)
|
|
- Changed: Plugin 3 send method, combined routines
|
|
- Changed: HomeConfort was recognized as Impuls, now using GDR2 name
|
|
- Changed: HomeEasy remotes can deliver various signals, now skipping KAKU compatible signals and just reporting the HomeEasy code when both codes are transmitted
|
|
- Fixed: HomeEasy group on/off command was reversed for HE8xx devices, now correctly detects differences between HE3xx and HE8xx
|
|
- Fixed: HomeEasy was not able to control HE87x switches, changed the entire transmit routine
|
|
- Changed: stretched Xiron timing checks
|
|
- Changed: Various timing modifications (NewKaku/AC, Blyss) due to the new timing introduced at version R26
|
|
- Changed: Plugin 61, Chinese Alarm devices, reversed bits as it seemed to correspond better to bit settings, increased address range
|
|
- Fixed: Flamingo Smokedetector packet detection tightened up to prevent false positives
|
|
- Fixed: Corrected Conrad RSL command interpretation
|
|
- Added: Extended Nodo Slave support to support separate and combined sensors
|
|
- Added: Extended Nodo Slave support to support pulse meters
|
|
|
|
R29:
|
|
- Fixed: AC/NewKaku high unit numbers were incorrect.
|
|
If you already have devices with high unit numbers in Domoticz, just throw them away and let them be recognized again
|
|
|
|
R28:
|
|
- Fixed: FA20RF smoke detector transmit from Domoticz
|
|
|
|
R27:
|
|
- Added: OSV1 battery status
|
|
- Fixed: OSV1 boundaries and removed some debug info
|
|
- Fixed: Some plugins set an incorrect sampling rate divider value
|
|
- Changed: AlectoV1 false positives filter was too agressive
|
|
|
|
R26:
|
|
- Added: QRFDEBUG command to do faster logging of undecoded data
|
|
- Added: VERSION command
|
|
- Added: Powerfix/Quigg switches
|
|
- Added: proper Lacrosse V3 WS7000 sensor support
|
|
- Changed: config file and plugin integration
|
|
- Changed: timeout and divider value
|
|
- Changed: Lacrosse V2 WS2300/WS3600 plugin number to get faster processing, changed various other parts as well
|
|
- Changed: Lacrosse V1 pulse duration checks
|
|
- Changed: various parts to improve speed
|
|
- Changed: Flamingo Smoke detector signal re-transmits from 8 to 10 times
|
|
- Added: Additional tests on Alecto V1 and Alecto V4 to filter out false positives
|
|
- Fixed: AC (NewKaku) protocol send for some device numbers
|
|
- Fixed: little bug in UPM code
|
|
- Fixed: Oregon wind speed reporting
|
|
- Fixed: Wind speed calculations
|
|
- Fixed: Wind direction reporting in all plugins
|
|
- Fixed: AlectoV3 humidity value displaying out of range values
|
|
- Fixed: OregonV1 decoding
|
|
|
|
R25:
|
|
- Fixed: Eurodomest address range check
|
|
- Fixed: Alecto V1 and V3 humidity handling
|
|
- Fixed: Lacrosse WS2300/WS3600 and labelled as LacrosseV2
|
|
|
|
R24:
|
|
- Fixed: Flamingo Smoke Detector timings and device address usage
|
|
- Fixed: Timing for Nexa/Jula Anslut
|
|
|
|
R23:
|
|
- Changed: Alecto V1 temperature data filtering
|
|
- Added: Alecto V1 battery status now shown for temperature sensors
|
|
|
|
R22:
|
|
- Various additional tests and fixes after intensive tests
|
|
- Added: Home Confort send and recognition by Domoticz
|
|
|
|
R21:
|
|
- Re-Activated PIR & Door/Window sensors (plugin 60/61)
|
|
|
|
R20:
|
|
- Switched to Arduino 1.6.5
|
|
|
|
R19:
|
|
- Complete rewrite
|
|
- Added: Home Confort Smart Home - TEL-010
|
|
- Added: RGB LED Controller
|
|
- Added: RL-02 Digital Doorbell
|
|
- Added: Deltronic Doorbell
|
|
- Added: Sartano 2606 remote & switch
|
|
|
|
r18:
|
|
- Added Banggood SKU174397, Sako CH113, Homemart/Onemall FD030 and Blokker (Dake) 1730796 outdoor temperature sensor
|
|
- Tested Okay: Promax RSL366T, Profile PR-44N & PR-47N
|
|
- Fixed: LaCrosse humidity values are correctly displayed
|
|
- Fixed: Humidity values that originate from slave Nodos are correctly displayed
|
|
- Fixed: UPM/Esic insane temperature values are skipped
|
|
- Removed Xiron & Auriol debug data
|
|
- Tightened pulse range on various protocols to prevent false positives
|
|
|
|
r17:
|
|
- Modified Oregon THGR228N code,
|
|
- Modified Newkaku(AC) dim values,
|
|
- Corrected support for KAKU door switches,
|
|
- Fixed Nodo Slave sensors,
|
|
- Improved speed and priorities so that group commands are properly transmitting
|
|
|
|
r16:
|
|
- Fixed Aleco V1 temperature ID to match wind sensors
|
|
- Fixed HomeEasy transmit
|
|
- Added AC(NewKaku) dimmer support
|
|
|
|
r15:
|
|
- Improved large packet translation
|
|
|
|
r14:
|
|
- Changed Motion sensors (60/61)
|
|
|
|
r13:
|
|
- Flamingo Smoke detector fix
|
|
- Added Xiron sensor support
|
|
|
|
r11/12:
|
|
- Mertik / Dru Send added
|
|
|
|
r10:
|
|
- Added Auriol Z32171A
|
|
|
|
r9:
|
|
- Fixed Kaku send with high device id's (P1 M1 etc)
|
|
|
|
r8:
|
|
- Improved descriptions
|
|
|
|
r7:
|
|
- Fixed Oregon RTGR328N ID and humidity format
|
|
- Fixed UPM/Esic humidity format
|
|
- Fixed Alecto humidity format
|
|
|
|
r6:
|
|
- Fixed Auriol V2 plugin
|
|
- Updated Auriol plugin
|
|
- Fixed Lacrosse Humidity
|
|
|
|
r1/2/3/4/5:
|
|
- Added X10 receive/transmit plugin
|
|
- Minor changes & improvements
|
|
|
|
|
|
Special thanks to:
|
|
Alex, Benoit, Bert, Christophe, Deennoo, Emmanuel, Gerrit, Goran, Graeme, Jelle, John, Jonas, Marek, Mark, Martinus, Maurice,
|
|
Paul, Pim, Remco, Richard, Rob, Sebastien, Thibaut, William
|
|