Tuya AC for docs Node red

Send the following payload to TuYa node

  • For one command: {"set":<Value>,"dpsIndex":<IndexID>}
  • For Multiple commands: [{"set":<Value>,"dpsIndex":<IndexID>},{"set":<Value>,"dpsIndex":<IndexID>}]

Value can be

  • Boolean: true or false
  • Integer: 1
  • String: "Value"

IndexID

Index Usage ValueType Values
1 AC Power Boolean true, false
4 Timer* State Integer 1, 2
5 Mode Integer 0 (Do Not use), 1 (Heating), 2 (Dehumidify), 3 (Cool), 4 (Ventilation)
6 SetPoint (in °C) Integer 13 t/m 32
8 FanSpeed* Integer 0 (Auto), 1 (Low), 2 (Medium), 3 (High)
10 Temp unit on display Boolean true (Celsius), false (Fahrenheit)
13 Turn off timer* (in minutes) Integer 0 t/m 1440
14 Turn on timer* (in minutes) Integer 0 t/m 1440
15 Retruns error code String LT (Low Temperature), PG (Probe Failure) / FT (Full Tank)
16 Swing* Boolean true, false
17 Sleep/ECO Boolean true, false
18 SetPoint (in °F) Integer 55 t/m 90
19 Force* Boolean true, false
  • Timer: Timer State and On/Off timer must both be set
  • FanSpeed: 'Auto' is unavailable when using 'Ventilation' mode
  • Swing: Unavailable using 'Heating' mode
  • Force: This does not seem to do anything at the moment